Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
MedComm (2020) ; 5(5): e550, 2024 May.
Article in English | MEDLINE | ID: mdl-38645662

ABSTRACT

Three-dimensional (3D) echocardiography is an emerging technique for assessing right ventricular (RV) volume and function, but 3D-RV normal values from a large Chinese population are still lacking. The aim of the present study was to establish normal values of 3D-RV volume and function in healthy Chinese volunteers. A total of 1117 Han Chinese volunteers from 28 laboratories in 20 provinces of China were enrolled, and 3D-RV images of 747 volunteers with optimal image quality were ultimately analyzed by a core laboratory. Both vendor-dependent and vendor-independent software platforms were used to analyze the 3D-RV images. We found that men had larger RV volumes than women did in the whole population, even after indexing to body surface area, and older individuals had smaller RV volumes. The normal RV volume was significantly smaller than that recommended by the American Society of Echocardiography/European Association of Cardiovascular Imaging guidelines in both sexes. There were significant differences in 3D-RV measurements between the two vendor ultrasound systems and the different software platforms. The echocardiographic measurements in normal Chinese adults II study revealed normal 3D-RV volume and function in a large Chinese population, and there were significant differences between the sexes, ages, races, and vendor groups. Thus, normal 3D-RV values should be stratified by sex, age, race, and vendor.

2.
Int J Cardiol ; 403: 131886, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38382850

ABSTRACT

BACKGROUND: A novel automated method for measuring left ventricular (LV) global longitudinal strain (GLS) along the endocardium has advantages in terms of its rapid application and excellent reproducibility. However, it remains unclear whether the available normal range for conventional GLS using the manual method is applicable to the automated GLS method. This study aimed to compare automated GLS head-to-head with manual layer-specific GLS, and to identify whether a specialized normal reference range for automated GLS is needed and explore the main determinants. METHODS: In total, 1683 healthy volunteers (men, 43%; age, 18-80 years) were prospectively enrolled from 55 collaborating laboratories. LV GLS was measured using both manual layer-specific and automated methods. RESULTS: Automated GLS was higher than endocardial, mid-myocardial, and epicardial GLS. Women had a higher automated GLS than men. GLS had no significant age dependency in men, but first increased and then decreased with age in women. Accordingly, sex- and age-specific normal ranges for automated GLS were proposed. Moreover, GLS appeared to have different burdens in relation to dominant determinants between the sexes. GLS in men showed no dominant determinants; however, GLS in women correlated with age, body mass index, and heart rate. CONCLUSIONS: Using the novel automated method, was LV GLS higher than when using the manual GLS method. The normal ranges of automated GLS stratified according to sex and age were provided, with dominant determinants showing sex disparities that require full consideration in clinical practice.


Subject(s)
Echocardiography , Global Longitudinal Strain , Male , Humans , Female , Adolescent , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over , Reference Values , Echocardiography/methods , Ventricular Function, Left/physiology , Reproducibility of Results
3.
Eur Heart J Cardiovasc Imaging ; 24(10): 1384-1393, 2023 09 26.
Article in English | MEDLINE | ID: mdl-37530466

ABSTRACT

AIMS: Mitral annular plane systolic excursion (MAPSE) is a simple and reliable index for evaluating left ventricular (LV) systolic function, particularly in patients with poor image quality; however, the lack of reference values limits its widespread use. This study aimed to establish the normal ranges for MAPSE measured using motion-mode (M-mode) and two-dimensional speckle tracking echocardiography (2D-STE) and to explore its principal determinants. METHODS AND RESULTS: This multicentre, prospective, cross-sectional study included 1952 healthy participants [840 men (43%); age range, 18-80 years] from 55 centres. MAPSE was measured using M-mode echocardiography and 2D-STE. The results showed that women had a higher MAPSE than men and MAPSE decreased with age. The age- and sex-specific reference values for MAPSE were established for these two methods. Multiple linear regression analyses revealed that MAPSE on M-mode echocardiography correlated with age and MAPSE on 2D-STE with age, blood pressure (BP), heart rate, and LV volume. Moreover, MAPSE measured by 2D-STE correlated more strongly with global longitudinal strain compared with that measured using M-mode echocardiography. CONCLUSION: Normal MAPSE reference values were established based on age and sex. BP, heart rate, and LV volume are potential factors that influence MAPSE and should be considered in clinical practice. Normal values are useful for evaluating LV longitudinal systolic function, especially in patients with poor image quality, and may further facilitate the use of MAPSE in routine assessments.


Subject(s)
Echocardiography , Mitral Valve , Male , Humans , Female , Adolescent , Young Adult , Adult , Middle Aged , Aged , Aged, 80 and over , Reference Values , Prospective Studies , Cross-Sectional Studies , Mitral Valve/diagnostic imaging , Echocardiography/methods , Ventricular Function, Left/physiology
4.
Chemosphere ; 307(Pt 1): 135731, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35843426

ABSTRACT

The levels of legacy per- and polyfluoroalkyl substances (PFASs) have been growing in the environmental matrices and blood of residents living around the fluorochemical industrial park (FIP) in Fuxin of China over the past decade. Although some recent studies have reported occurrence of novel PFAS alternatives in biotic and abiotic matrices near fluorochemical facilities worldwide, little is known about novel PFAS congeners in maternal sera, umbilical cord sera, and placentas from the female residents close to the FIP and their related health risks. In this study, 50 paired samples of maternal and cord serum as well as placenta were derived from Fuxin pregnant women at delivery, and 21 target analytes of legacy PFASs in all the samples were analyzed via high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS), revealing that PFBS, PFBA, and PFOA were the dominant PFAS contaminants observed in the whole samples. Based upon the suspect screening through high-resolution mass spectrometry (HRMS), 49 novel PFASs assigned to 11 classes were further identified in the Fuxin samples, of which, 20 novel congeners in 4 classes were reported in human blood and placentas for the first time. Moreover, the coefficients for mother-placenta transfer (Rm/p), placenta-newborn transfer (Rp/n), and mother-newborn transfer (Rm/n) of legacy PFASs could be calculated with median values of 1.7, 1.1, and 2.0, respectively, and Rm/p, Rp/n, and Rm/n for each novel PFAS identified were also estimated with the median values of 0.9, 1.2, and 0.8 individually. Accordingly, novel PFASs contributed 90% of all the legacy and novel PFASs in maternal sera and even occupied 96% of the whole PFASs in both placentas and cord sera. In addition, significant associations were determined among the neonate birth outcomes and serum concentrations of thyroid hormone, sex hormone, and glucocorticoid, together with the levels of certain legacy and novel PFASs in cord sera.


Subject(s)
Alkanesulfonic Acids , Fluorocarbons , Alkanesulfonic Acids/analysis , China , Female , Fluorocarbons/analysis , Glucocorticoids , Humans , Infant, Newborn , Placenta/chemistry , Pregnancy , Tandem Mass Spectrometry , Umbilical Cord
5.
Med Sci Monit ; 23: 3585-3592, 2017 Jul 23.
Article in English | MEDLINE | ID: mdl-28735336

ABSTRACT

BACKGROUND The aim of this study was to investigate the feasibility of using acoustic radiation force impulse (ARFI) elastography, AST-to-platelet ratio index (APRI), and FIB-4 in assessing liver fibrosis and free portal pressure in patients with hepatitis B. MATERIAL AND METHODS We enrolled 126 patients with hepatitis B who underwent liver surgery at the General Surgery Department of the First Affiliated Hospital of Shihezi University Medical School from February 2013 to August 2015. Preoperatively, shear wave velocity (SWV) of the liver was measured with the Siemens S2000 ultrasound system to reflect liver stiffness. Serological markers were collected and fibrosis indices APRI and FIB-4 were calculated. Intraoperatively, liver tissues were harvested and free portal pressure (FPP) was measured. Postoperatively, fibrosis of liver tissues was pathologically staged. RESULTS The results of SWV, APRI, FIB-4, and FPP were all correlated with the degree of liver fibrosis (Spearman correlation coefficients: r=0.777, P<0.001; r=0.526, P<0.001; r=0.471, P<0.001; p<0.000; r=0.675, p<0.000). Receiver operating characteristic curve (ROC) analysis showed that the areas under the curve (AUC) of ARFI, APRI, and FIB-4 in diagnosing liver fibrosis were 0.830, 0.768, and 0.717, respectively, for stage F≥1; 0.861, 0.773, and 0.754, respectively, for stage F≥2; 0.941, 0.793, and 0.779, respectively, for stage F≥3; and 0.945, 0.783, and 0.754, respectively, for stage F=4. SWV, APRI, and FIB-4 were all correlated with FPP (Pearson correlation coefficients: 0.387, P<0.001; 0.446, P<0.001; 0.419, P<0.001). CONCLUSIONS ARFI, APRI, and FIB-4 can assess liver fibrosis in patients with hepatitis B when assessing the portal venous pressure. The difference in diagnostic efficacy between the 3 was not significant.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Cirrhosis/diagnostic imaging , Adult , Aged , Area Under Curve , Biomarkers/blood , Biopsy , Female , Hepatitis B/diagnostic imaging , Hepatitis B/physiopathology , Hepatitis B, Chronic/diagnostic imaging , Hepatitis C, Chronic/diagnostic imaging , Humans , Liver/diagnostic imaging , Liver Cirrhosis/metabolism , Male , Middle Aged , Portal Pressure/physiology , ROC Curve , Ultrasonography
6.
Med Sci Monit ; 23: 2241-2249, 2017 May 12.
Article in English | MEDLINE | ID: mdl-28496092

ABSTRACT

BACKGROUND The aim of this study was to investigate the usefulness of contrast-enhanced ultrasonography (CEUS) in predicting of esophageal varices (EV) and assessing high-risk EV in patients with hepatitis B virus (HBV)-related cirrhosis. MATERIAL AND METHODS Patients with HBV-related cirrhosis who had undergone endoscopy were prospectively recruited. Hepatic dynamic CEUS was performed. Regions of interest (ROI) were drawn on the hepatic artery, hepatic vein, portal vein, and liver parenchyma to measure the corresponding features, such as arrival times. Spearman's correlation analysis was used to determine the relations between several dynamic CEUS features and the degree of EV. Receiver operating characteristics (ROC) curves were constructed to investigate the diagnostic performance of CEUS in assessing the presence of EV and high-risk EV. RESULTS Fifty-eight patients (44 men; mean age 51.3 years) were included in this study. Of these, 18 (31.0%), 12 (20.7%), 11 (19.0%), and 17 (29.3%) of patients had grade 0, 1, 2, and 3 EV, respectively. Grade 2 and grade 3 EV were considered high-risk EV. Among the CEUS features, the area under the ROC curves of intrahepatic transit time (HV-HA, i.e., the difference between hepatic vein arrival time and hepatic artery arrival time) both for assessment of the presence of EV and high-risk EV (0.883 and 0.915, respectively) were larger than the other indices. HV-HA was negatively correlated with the grade of EV. An HV-HA of under 8.2 s indicated the presence of EV and under 7 s indicated high-risk EV. CONCLUSIONS Dynamic CEUS imaging is useful in assessing the presence of EV and high-risk EV in patients with HBV-related cirrhosis.


Subject(s)
Contrast Media/chemistry , Esophageal and Gastric Varices/diagnostic imaging , Esophageal and Gastric Varices/virology , Hepatitis B virus/physiology , Liver Cirrhosis/diagnostic imaging , Liver Cirrhosis/virology , Ultrasonography , Adult , Esophageal and Gastric Varices/complications , Female , Humans , Liver Cirrhosis/complications , Male , Middle Aged , ROC Curve , Risk Factors , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...